District Heating: Daikin Containerized Solutions for Reliable Heat

In Europe, district heating already represents an essential component of the energy transition. According to Euroheat & Power, district heating and cooling networks cover approximately 13% of the final heat demand for space heating and domestic hot water, serving over 77 million citizens through more than 19,000 networks. The sector continues to expand across major European markets thanks to investments in decarbonization, renewable energy integration, and waste heat recovery.

In this scenario, the challenge lies not only in reducing the use of fossil fuels, but also in doing so while ensuring service continuity, adherence to project schedules, and integration with existing infrastructure. Heat pumps are emerging as one of the most effective technologies to achieve these objectives, especially when incorporated into solutions designed to simplify their implementation.

Contact the Daikin team to find out how to integrate high-efficiency heat pumps into your district heating plants quickly, flexibly, and reliably.

 

What types of district heating networks are widespread in Europe?

In Europe, district heating covers approximately 12–13% of the overall thermal demand, exceeding 50% in Nordic and Baltic countries. Traditionally powered by cogeneration, waste-to-energy, and biomass, these infrastructures are increasingly integrating renewables and waste heat. Supply temperature divides them into four main categories: Traditional networks (3rd generation, 70–90 °C): still predominant in European cities, they serve existing buildings without requiring modifications to internal systems. High-temperature networks (2nd generation, greater than 100 °C): typical of large historic metropolitan systems (e.g., Paris, Berlin, Warsaw), suitable for transporting large amounts of heat over long distances. Low-temperature networks (4th generation, 40–60 °C): widespread in new high-efficiency districts (e.g., Nordhavn in Copenhagen), they reduce heat losses but often require a local temperature boost for domestic hot water. Cold networks (5th generation, 8–25 °C): they exploit low-enthalpy sources and rely on decentralized heat pumps in buildings for temperature boosting, also allowing for summer cooling. In this context, heat pumps play a key role in achieving the European objectives of the Fit for 55 package. According to Euroheat & Power and the IEA, over 300 large heat pumps integrated into networks are already active in Europe (for over 1.5 GW of capacity), which are necessary to valorize urban waste heat (data centers, sewage systems, industries), which in most cases is below 25–30 °C. Depending on the network, heat pumps can directly feed low-temperature circuits or act as an intermediate stage to raise the water temperature before feeding it into existing networks, cutting fossil fuels and CO₂ emissions without compromising service continuity. Want to discover how heat pumps can accelerate the decarbonization of district heating networks? Contact our specialists and discover the solution best suited to your network's needs.

 

How is heat generated in district heating networks in Europe?

European district heating networks can be powered by a single production plant, multiple interconnected plants, or a combination of main plants and distributed injection points across the territory. This configuration allows operators to adapt production to seasonal demand and progressively integrate new energy sources without compromising service continuity. Historically, much of the heat distributed in Europe has been produced from fossil fuels (especially natural gas in Western and Southern Europe, with historical shares of coal in Central and Eastern Europe) through high-efficiency combined heat and power (CHP) plants and waste-to-energy plants. Today, however, the energy mix is evolving rapidly: at the EU level, renewable sources and waste heat already cover over a third of the energy fed into networks (exceeding 60–70% in Nordic and Baltic countries). Alongside traditional technologies, solid biomass (predominant in the Baltic and Scandinavian areas), geothermal energy (with centers of excellence in France, Hungary, Iceland, and Italy), and heat recovery from industrial processes are gaining increasing ground, in line with the European goals of the Fit for 55 package. In this context, large-scale heat pumps (greater than 1 MW) and electric boilers (e-boilers) are taking on a strategic role. Installed at existing plants or near low-temperature sources, they allow the valorization of energy from the environment (seawater, river water, or groundwater), wastewater, or industrial heat recovery, helping to reduce fossil fuel consumption and balance the power grid (sector coupling). According to Euroheat & Power reports, in the European Union the installed capacity of large heat pumps in district heating has already reached around 2.5 GW thermal, with an expected expansion of over 80% by 2030 and flagship projects such as the tens-of-megawatts plants in Vienna, Stockholm, and Cologne, confirming their central role in the transition toward more sustainable and efficient networks.

 Discover Daikin heat pumps for sustainable district heating and contact our experts for a dedicated consultation.

What district heating projects are planned?

Interventions involve new networks, extensions, generation renewal, and the creation of local networks. Each type requires a different assessment of the capacity to be installed and the integration conditions. In new networks, heat pumps can form the basis of thermal production, designing distribution temperatures and user needs together. In the renewal of an existing plant, they can supplement or replace part of the fossil generation, retaining other generators for peak loads and backup. In network extensions, they can provide the necessary additional capacity, either at the main plant or through a new injection point near the users, depending on the transport capacity of the pipes. A district with lower temperatures can also be served by a dedicated section, in which heat pumps are selected based on local conditions. For distant areas or those developed in phases, an autonomous local network powered by heat pumps can represent an alternative to the immediate extension of the main network, preparing for possible future interconnection. Their use can therefore be evaluated across various project types, identifying the configuration consistent with available sources and required temperatures.

When and why to use heat pumps in district heating projects?

In Europe, the energy transition in the heating sector—which accounts for about 50% of final EU energy consumption—is strengthening the role of heat pumps both in buildings and in district heating networks. The progressive electrification of thermal consumption, driven by European directives on energy efficiency (EED) and renewable energy sources (RED III, which mandates an annual increase in the share of renewables and waste heat in networks), is encouraging the adoption of technologies capable of valorizing local sources and reducing dependence on imported fossil fuels. In this scenario, heat pumps emerge as one of the key solutions to modernize European thermal infrastructure. This evolution is supported by rapid technological development, which enables their use in both residential and commercial buildings as well as in district heating plants, where they recover energy from environmental sources (seawater, river water, and groundwater), industrial processes, wastewater, or data centers. In district heating, heat pumps are particularly advantageous when they can exploit a stable local thermal source—such as surface water, wastewater, or industrial waste heat—reducing reliance on gas or biomass boilers. The most favorable operating conditions (with seasonal COPs between 3 and 4.5) occur when network temperatures fall within the optimal range of the machines and when the temperature lift between the source and the produced water is contained, thus limiting electricity consumption. Even in the presence of existing networks with high supply temperatures, high-temperature heat pumps or multi-stage configurations can be used (as demonstrated by the large plants launched in Vienna, Stockholm, or Mannheim). However, economic feasibility must be evaluated over the entire annual operating profile: heat production costs (LCOH - Levelized Cost of Heat) are compared with fossil or biomass alternatives, taking into account the spark spread (the ratio between electricity and gas prices) and the electrical power available for grid connection. Properly sizing a heat pump means establishing how much thermal power to install in relation to the network's annual load duration curve. By sizing it for the base load—typically around 20–40% of peak power—it can operate for 4,000–6,000 hours per year, covering up to 60–80% of the annual thermal energy and leaving existing generators (gas boilers or e-boilers) to cover short-duration winter peaks and act as backup. This approach contains initial investment (CAPEX) and the required electrical connection capacity, gradually transforming the plant with an economic return commensurate with actual production. Modularity also makes it possible to keep pace with user expansion. Preparing spaces, hydraulic connections, and control logics for subsequent expansions allows standardized units to be added as demand grows, avoiding tying up all capital immediately. In existing plants, this approach also facilitates phased work planning: defining when to integrate new production, how to interface it with control systems, and which generators to keep active during revamping is decisive in ensuring service continuity for residential and industrial users. Finally, heat pumps enable distributed heat generation. This makes it possible to develop autonomous or satellite district networks without necessarily having to extend a high-temperature main trunk line, reducing investments in underground infrastructure, permitting times, and heat losses. For a contractor or designer, identifying these parameters early allows them to propose a technical and economic configuration perfectly aligned with the project schedule and the future development of the served area.

How to choose a custom solution while meeting project schedules

In district heating projects, customization and work predictability must go hand in hand. A plant designed for a specific site must meet temperatures, capacity, and available spaces, but also requires careful coordination between equipment, hydraulic connections, and control systems. Daikin's containerized solution addresses these needs through a pre-engineered base that is adaptable to the project. The indicative range provided is 100–400 kW per single container, with actual configuration and capacity defined according to application conditions. Engineering takes into account the type of network, required temperatures, and selected refrigerant. The container can therefore constitute a plant for a local network or an integrative element of a larger system. One of the configurations considered combines water-to-water heat pumps inside the container with external air-to-water units. Depending on the hydraulic scheme, the outdoor units help maintain conditions compatible with the operation of the water-to-water machine on the circuits associated with the evaporator and condenser. For high-temperature water-to-water applications, the EWWH-VZ series uses R-1234ze refrigerant and a Daikin inverter screw compressor, producing hot water up to 90 °C. Another configuration involves exclusively air-to-water heat pumps integrated into the container, with a layout designed for heat exchange with outdoor air. The options indicated include the EWYT-CZ series with R-32 and the modular EWYK-QZ series with R-290, which can be combined in groups of four modules. The latter can produce water up to 75 °C and can be evaluated for networks with compatible thermal requirements. For the contractor, the benefit of pre-engineering mainly concerns interface management. Starting from an already developed configuration allows checks to focus on site differences and enables connections and on-site activities to be defined in advance. Replicability also fosters effective management of a strategy based on innovation, sustainability, and customer proximity. For district heating projects, as well as for the most demanding industrial applications, Daikin provides contractors with a single point of contact, capable of supporting every phase of the project, from initial technical consultation to operational management and post-installation services, helping to reduce risks, accelerate implementation, and maximize long-term plant reliability—all the more uniform when the same project includes multiple local plants or subsequent expansion phases. Configuration validation by the supplier helps verify the compatibility of components and operating logics prior to integration. The scope of checks and on-site activities is agreed upon for each individual order. This approach can reduce execution uncertainties and support plant reliability, without replacing network design verifications.

How to choose a reliable partner for district heating projects?

For contractors engaged in the development of complex plants, a partner's reliability is measured not only by the quality of the technologies offered, but also by the ability to provide qualified support throughout the entire project lifecycle. From this perspective, Daikin Applied Europe has established itself as a benchmark in the HVAC sector, combining application expertise, experience in managing complex projects, and a structured organization to support industrial and mission-critical applications. Daikin Applied Europe continues to invest in developing decarbonization solutions, expanding its range of heat pumps and chillers with natural refrigerants such as R-290 and high-temperature systems for industrial applications and district heating networks, developed in the new dedicated research and development center at the Ariccia (Rome) headquarters, inaugurated in 2024 following a 16-million-euro investment. This investment is part of a broader framework, under which over the last 10 years new production and product development facilities worth over 30 million euros have been built, alongside steadily growing revenue that now stands at 504 million euros.

Rely on Daikin for qualified support at every stage of the project: contact our experts for a dedicated consultation.